A networked scalable access controller - suitable for small or medium scaled security system.
-
Physical size of each controller (L x W x D) mm: 140 x 90 x 23
-
Operating voltage DC 12V at 700mA
It is an ideal solution requiring economical, fast installation with modest resources that is applicable to both commercial and institutional environment. A powerful, flexible and easy to use software manages a network of such controllers, hence making it easy to monitor transactions of accesses and users. Any of these RFID Proximity, PIN, PRox & PIN, and smartcard readers can be seemlessly integrated with each of such controller.
Application environment:
-
Number of doors in a networked system: between 1 and 64
-
Communication buses: max. 4
-
Number of networkable doors per bus: 16
-
Number of readers per controller: max. 2 (IN and OUT directions)
-
Installation: Mountable into a metal enclosure integrated with switching power supply/charger.
-
Communication to readers: Wiegand-26
-
Communication to software: RS-232 (max 10ft or 3m), or RS-485 (max 1Km)
-
Software name: mPoint (Charges free, for 16 doors)
-
Software required OS: Microsoft Windows XP or later
-
Software required Database: Microsoft SQL 2005 Express Edition
Functional features:
-
Number of users: 1000 max.
-
Number of transactions: 1000
-
PIN codes for entry: 50 max.
-
Card format: 26-bit Wiegand
-
-
Facility code support: 4 digits, between 0000 and 0255
[9999 max if free-Wiegand, not applicable to this controller]
-
Anti-pass back: Local (availability of anti-pass back by groups of networked doors would be dependent to an offered software server engine)
-
Anti-pass back aplication only to selected cards: Yes
-
Database checking mode: Igore or Check
-
Data communication speed: 9600 or 19200 bps
-
-
Time zones
-
Time zones for accesses: 30 max.
-
Time Zone for disabling PIN [in a PIN & Card mode]: Available
-
Time zone for auto-unlocking door: Available
-
-
Input and output signals
-
Input signal: for exit push button
-
Output signal: 1 (generally used for addtional buzzer)
-
Ouput alarm: trigger by door left open
-
-
Software scope: door access control and basic time attendance reporting
Information on convenience in system-upgrade :
-
System upgrade: Easy
-
System free upgradable components:
Firmware through software
Software through technical support
Basic time attendance through technical support
|